| Sign In | Join Free | My chinabagsnet.com | 
              
  | 
      
Brand Name : ESEGAS
Model Number : ESE-LASER-100
MOQ : 1 unit
Payment Terms : T/T
Delivery Time : 14 working days
Name : Environmental Monitoring Laser Gas Analyser
Response time (T90) : ≤30s
Analog output : 4-20mA output (isolation, maximum load 750Ω)
Digital communication : RS485/RS232/GPRS
Power : 100VAC ~ 240VAC
Repeatability : ≤1%
Principle : Tunable Diode Laser Absorption Spectroscopy (TDLAS) Technology
Laser Gas Analysis TDLAS Technology 19 Inch NH3/HCL/HF/H2S/CO/CO2/O2
Laser gas analysis is a technique for measuring the composition of a gas sample. It uses a laser to excite the molecules in the sample, and then measures the amount of light that is emitted by the molecules. The amount of light that is emitted depends on the type of molecule, so this information can be used to determine the composition of the sample.
Laser gas analysis is used in a variety of applications, including:
- Industrial process control
- Environmental monitoring
- Medical diagnostics
- Research and development
Laser gas analysis is a versatile technique that can be used to measure a wide range of gases. It is also a relatively fast and accurate technique, and it can be used to measure gases in a variety of environments.
Here are some of the benefits of using laser gas analysis:
- It is a fast and accurate technique.
- It can be used to measure a wide range of gases.
- It can be used in a variety of environments.
- It is a versatile technique that can be used for a variety of applications.
Laser gas analysis is a valuable tool that can be used to measure the composition of gas samples. It is a fast, accurate, and versatile technique that can be used in a variety of applications.
ESE-LASER-200 Laser Gas Analyser is a 19" 4U TDLAS gas analyzer for industrial online analysis .The gas analyzer combine multiple reflection long optical path technology that can analysis gas including NH3,HCL,HF,CH4,H2S,CO,CO2,O2 .
Specifiications
| Linearity Error | ≤±1%FS | 
| Repeatability | ≤±1% | 
| Zero Drift | ≤±1%FS/half year | 
| Span Drift | ≤±1%FS/half year | 
| Calibration Cycle | ≤2 times/year | 
| Response time | ≤30S | 
| Interface Signal | |
| Analog Output | 2*4-20mA output | 
| Analog Input | 2*4-20mA output | 
| Digital Output | RS485/RS232/GPRS | 
| Relay Output | 3(24V,1A) | 
| Operating Conditions | |
| Power Supply | 100VAC-240VAC | 
| Purge Gas | 0.3Mpa-0.8Mpa | 
| Ambient Temperature | ’-20℃-+60℃ | 
| 
                                             | 
                
                        Environmental Monitoring Laser Gas Analyser NH3 HCL HF H2S CO CO2 O2 Images |