Brand Name : ESEGAS

Model Number : ESE-LASER-100

MOQ : 1 unit

Payment Terms : T/T

Delivery Time : 14 working days

Repeatability : ≤1%

Response time (T90) : ≤30s

Analog output : 4-20mA output (isolation, maximum load 750Ω)

Digital communication : RS485/RS232/GPRS

Principle : Tunable Diode Laser Absorption Spectroscopy (TDLAS) Technology

Power : 100VAC ~ 240VAC

Contact Now

HCL gas analyzer TDLAS technology 19 inch NH3 HCL HF H2S CO CO2 O2

An HCl gas analyzer is an instrument designed to measure the concentration of hydrogen chloride (HCl) gas in industrial processes. Hydrogen chloride is a corrosive and toxic gas that is commonly found in applications such as chemical manufacturing, metal refining, and combustion processes. Monitoring HCl levels is important for process control, environmental compliance, and worker safety.


Here are some key points about HCl gas analyzers:


1. Measurement Principle: HCl gas analyzers utilize various detection technologies to measure hydrogen chloride concentrations. Common methods include non-dispersive infrared (NDIR) absorption spectroscopy, electrochemical sensing, and titration. NDIR analyzers measure the absorption of infrared light by hydrogen chloride molecules, electrochemical sensors generate an electrical signal proportional to the HCl concentration, and titration analyzers use a chemical reaction to quantify the HCl concentration. Each method provides accurate and real-time measurements.


2. Features: HCl gas analyzers are designed for continuous monitoring in industrial environments and offer features suitable for process control. These may include:


- Robust Construction: Process analyzers are typically built to withstand harsh industrial conditions, with durable housings and components that resist corrosion and tolerate high temperatures.
- Remote Monitoring and Control: Some analyzers can be integrated into a control system or network, enabling remote monitoring and control of HCl levels. This facilitates real-time data access and allows for proactive response to changes in HCl concentrations.
- Data Logging and Reporting: Process analyzers often have built-in data logging capabilities to store measurement data over time. They can generate reports and provide data for compliance purposes, process optimization, and historical analysis.
- Alarm Systems: Process analyzers may include configurable alarms that trigger when HCl concentrations exceed predefined thresholds. Alarms alert operators to potential safety hazards, process issues, or deviations from desired operating conditions.
- Calibration and Maintenance: Regular calibration and maintenance are necessary to ensure accurate and reliable measurements. The frequency of calibration and maintenance depends on the specific analyzer and manufacturer's recommendations.


3. Measurement Range and Accuracy: HCl gas analyzers have specific measurement ranges and accuracies tailored for industrial applications. The measurement range can vary depending on the model and may cover low parts-per-million (ppm) levels up to high percentages by volume. The accuracy of the measurements is specified by the manufacturer and can vary between models.


4. Safety Considerations: Hydrogen chloride is a highly corrosive and toxic gas. When working with HCl and HCl gas analyzers, it is crucial to follow proper safety protocols. This includes ensuring proper ventilation, using appropriate personal protective equipment, and implementing gas detection systems and emergency shutdown procedures.

5. High Selectivity: TDLAS technology offers high selectivity for the target gases, minimizing interference from other components in the gas mixture.

6. Non-Intrusive Measurement: TDLAS technology allows for non-intrusive measurement, meaning it doesn't require direct contact with the gas stream.


It's important to note that specific HCl gas analyzer models may have additional features and specifications, so it is recommended to consult the manufacturer's documentation or user manual for detailed information on a particular device.

ESE-LASER-200 Laser Gas Analyser is a 19" 4U TDLAS gas analyzer for industrial online analysis .The gas analyzer combine multiple reflection long optical path technology that can analysis gas including NH3,HCL,HF,CH4,H2S,CO,CO2,O2 .

Specifiications

Linearity Error ≤±1%FS
Repeatability ≤±1%
Zero Drift ≤±1%FS/half year
Span Drift ≤±1%FS/half year
Calibration Cycle ≤2 times/year
Response time ≤30S
Interface Signal
Analog Output 2*4-20mA output
Analog Input 2*4-20mA output
Digital Output RS485/RS232/GPRS
Relay Output 3(24V,1A)
Operating Conditions
Power Supply 100VAC-240VAC
Purge Gas 0.3Mpa-0.8Mpa
Ambient Temperature ’-20℃-+60℃

Product Tags:

19 Inch HCL Gas Analyzer

      

HCL Gas Analyzer TDLAS Technology

      
Quality 19 Inch HCL Gas Analyzer TDLAS Technology For Process Control wholesale

19 Inch HCL Gas Analyzer TDLAS Technology For Process Control Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Enviro Solutions Technology Co.,Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)